Chrome Slag
Showing all 12 results
QCRM-1-107Chrome Slag – 10.61% Cr2O3 – Columbus Stainless
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al2O3 | % | 26.13 | ±0.41 |
CaO | % | 11.08 | ±0.53 |
Cr2O3 | % | 10.61 | ±0.11 |
FeO | % | 6.61 | ±0.16 |
MgO | % | 18.42 | ±0.33 |
SiO2 | % | 25.67 | ±0.28 |
QCRM-1-107 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Chrome Slag and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-1-119Chrome Slag – 19.27% Cr2O3 – Samancor FMT Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al2O3 | % | 19.69 | ±0.37 |
CaO | % | 3.68 | ±0.16 |
Cr2O3 | % | 19.27 | ±0.19 |
FeO | % | 13.08 | ±0.25 |
MgO | % | 16.27 | ±0.27 |
SiO2 | % | 31.04 | ±0.51 |
QCRM-1-119 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Chrome slag and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-127Chrome Slag – 10.58% Cr2O3 – Tubatse Ferrochrome
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al2O3 | % | 25.599 | ±0.662 |
CaO | % | 3.208 | ±0.131 |
Cr2O3 | % | 10.581 | ±0.088 |
FeO | % | 7.141 | ±0.095 |
MgO | % | 19.709 | ±0.274 |
SiO2 | % | 33.876 | ±0.461 |
QCRM-1-127 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for chrome slag and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-1-132Chrome Slag – 16.947% Cr2O3 – Tubatse Ferrochrome
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al2O3 | % | 10.176 | ±0.185 |
CaO | % | 2.912 | ±0.131 |
Cr2O3 | % | 16.947 | ±0.174 |
FeO | % | 14.601 | ±0.159 |
MgO | % | 17.398 | ±0.231 |
SiO2 | % | 35.763 | ±0.540 |
QCRM-1-132 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for chrome slag and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-1-144Chrome Slag – 4.13% Cr2O3 – Columbus Stainless
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al2O3 | % | 12.64 | ±0.08 |
CaO | % | 0.439 | ±0.056 |
Cr2O3 | % | 43.91 | ±0.13 |
Feo | % | 21.20 | ±0.18 |
MgO | % | 11.32 | ±0.11 |
MnO | % | 0.246 | ±0.008 |
S | % | 0.009 | ±0.002 |
SiO2 | % | 7.76 | ±0.15 |
TiO2 | % | 0.470 | ±0.011 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
P | % | 0.004 | ±0.002 |
V2O5 | % | 0.267 | ±0.007 |
QCRM-1-144 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for chrome concentrate and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-1-156Chrome Slag – 16.04% Cr2O3 – Samancor FMT Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al2O3 | % | 20.11 | ±0.43 |
CaO | % | 3.72 | ±0.17 |
Cr2O3 | % | 16.04 | ±0.12 |
FeO | % | 11.05 | ±0.14 |
MgO | % | 15.99 | ±0.31 |
SiO2 | % | 34.26 | ±0.18 |
QCRM-1-156 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Chrome Slag and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-1-160Chrome Slag – 15.51% Cr2O3 – Samancor FMT Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al2O3 | % | 15.73 | ±0.44 |
CaO | % | 2.89 | ±0.12 |
Cr2O3 | % | 15.51 | ±0.17 |
FeO | % | 10.86 | ±0.18 |
MgO | % | 11.69 | ±0.19 |
SiO2 | % | 44.45 | ±0.53 |
QCRM-1-160 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Chrome Slag and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-164Chrome Slag – 11.95% Cr2O3 – Tubatse Alloy Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
CaO | % | 5.04 | ±0.11 |
Cr2O3 | % | 11.95 | ±0.12 |
FeO | % | 5.76 | ±0.08 |
MgO | % | 18.65 | ±0.29 |
SiO2 | % | 31.56 | ±0.38 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Al2O3 | % | 26.66 | ±0.26 |
V2O5 | % | 0.48 | ±0.06 |
QCRM-1-164 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Chrome Slag and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-203Chrome Slag – 8.31% Cr2O3 – Samancor Dikwena Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Cr2O3 | % | 8.31 | ±0.14 |
FeO | % | 4.98 | ±0.17 |
SiO2 | % | 30.76 | ±0.50 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Al2O3 | % | 30.49 | ±0.32 |
CaO | % | 4.91 | ±0.24 |
MgO | % | 18.29 | ±0.61 |
QCRM-1-203 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Chrome slag and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-223Chrome Slag – 7.45% Cr2O3 – Samancor Middelburg Ferrochrome Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al2O3 | % | 27.41 | ±0.29 |
Cr2O3 | % | 7.45 | ±0.15 |
FeO | % | 4.58 | ±0.11 |
MgO | % | 21.72 | ±0.28 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
CaO | % | 14.44 | ±0.77 |
SiO2 | % | 23.69 | ±0.27 |
QCRM-1-223 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Chrome Slag and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-223Chrome Slag
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al2O3 | % | 27.27 | ±0.20 |
Cr2O3 | % | 7.51 | ±0.12 |
FeO | % | 4.57 | ±0.09 |
MgO | % | 21.70 | ±0.22 |
SiO2 | % | 23.79 | ±0.21 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
C | % | 0.85 | ±0.05 |
Ca0 | % | 14.37 | ±0.46 |
QCRM-1-223 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Chrome Slag and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-227Chrome Slag
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al2O3 | % | 27.45 | ±0.22 |
Cr2O3 | % | 6.36 | ±0.11 |
FeO | % | 4.41 | ±0.06 |
MgO | % | 19.51 | ±0.34 |
SiO2 | % | 33.37 | ±0.31 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Ca0 | % | 8.50 | ±0.24 |
QCRM-1-227 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Chrome Slag and as a calibration standard for the calibration of equipment used for analysing similar materials.