Copper
Showing all 33 results
QCRM-5-043Copper Concentrate – 22.57% Cu; 17.9% Zn; 5.41% S – Kalahari Copperbelt, Botswana
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Cu | % | 22.57 | ±0.44 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | Units | Concentrations | Expanded uncertainty |
Al | % | 0.57 | ±0.09 |
Ca | % | 0.35 | ±0.04 |
Co | % | 0.82 | ±0.06 |
Cu (soluble) | % | 18.8 | ±1.9 |
Fe | % | 3.87 | ±0.52 |
Mg | % | 0.69 | ±0.09 |
Ni | % | 0.08 | ±0.03 |
Pb | % | 0.45 | ±0.04 |
S | % | 5.41 | ±0.21 |
Si | % | 3.12 | ±0.29 |
Zn | % | 17.9 | ±2.1 |
QCRM-5-043 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for copper concentrate and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-5-054Copper Ore – 0.57% Cu, 18.34% Fe – Palabora Mining Company
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.88 | ±0.04 |
Cu | % | 0.57 | ±0.01 |
Fe | % | 18.34 | ±0.48 |
S | % | 0.43 | ±0.04 |
Zn | % | 0.012 | ±0.004 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | Units | Concentrations | Expanded uncertainty |
Ca | % | 19.67 | ±0.51 |
Co | % | 0.010 | ±0.002 |
Cu (soluble) | % | 0.12 | ±0.01 |
Mg | % | 4.78 | ±0.13 |
Mn | % | 0.12 | ±0.01 |
Ni | % | 0.014 | ±0.002 |
Pb | % | 0.008 | ±0.004 |
Si | % | 3.92 | ±0.30 |
QCRM-5-054 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Ore and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-063Copper Ore – 0.34% Cu; 3.56% Fe; 2.88g/t Ag; 33.2% Si – Rio Tinto Kennecott, USA
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 3.89 | ±0.08 |
Ca | % | 1.80 | ±0.04 |
Co | % | 0.003 | ±0.002 |
Cu | % | 0.34 | ±0.01 |
Fe | % | 3.56 | ±0.12 |
Mg | % | 1.60 | ±0.05 |
Mn | % | 0.022 | ±0.005 |
Mo | % | 0.039 | ±0.002 |
Ni | % | 0.005 | ±0.002 |
Pb | % | 0.018 | ±0.002 |
S | % | 1.91 | ±0.06 |
Si | % | 33.2 | ±1.1 |
Zn | % | 0.015 | ±0.002 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Ag | g/t | 2.88 | ±0.88 |
As | ppm | 63 | ±23 |
Au | g/t | 0.21 | ±0.07 |
Bi | ppm | 13 | ±13 |
Cu (Soluble) | % | 0.04 | ±0.02 |
K | % | 3.11 | ±0.14 |
Na | % | 0.52 | ±0.16 |
Se | ppm | 18 | ±13 |
QCRM-5-063 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Ore and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-064Copper Concentrate – 14.93% Cu; 89.3g/t Ag; 1327ppm As – Rio Tinto Kennecott, USA
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Ag | g/t | 89.3 | ±1.5 |
Al | % | 2.10 | ±0.08 |
Ca | % | 1.06 | ±0.06 |
Cu | % | 14.93 | ±0.09 |
Fe | % | 18.00 | ±0.37 |
Mg | % | 1.39 | ±0.07 |
Mn | % | 0.023 | ±0.002 |
Mo | % | 0.98 | ±0.02 |
Pb | % | 0.242 | ±0.006 |
S | % | 22.06 | ±0.57 |
Si | % | 13.55 | ±0.75 |
Zn | % | 0.222 | ±0.008 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
As | ppm | 1327 | ±47 |
Au | g/t | 7.7 | ±1.6 |
Bi | ppm | 149 | ±42 |
Co | % | 0.008 | ±0.002 |
Cu (soluble) | % | 0.57 | ±0.10 |
K | % | 1.66 | ±0.15 |
Na | % | 0.23 | ±0.08 |
Ni | % | 0.008 | ±0.002 |
Se | ppm | 116 | ±22 |
QCRM-5-064 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Concentrate and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-068Molybdenum Concentrate – 52.15% Mo, 35.1% S; 0.40% Cu, 8.4g/t Ag – Rio Tinto Kennecott, USA
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Ag | g/t | 8.4 | ±2.6 |
Ca | % | 0.83 | ±0.04 |
Cu | % | 0.40 | ±0.02 |
Fe | % | 0.74 | ±0.07 |
Mg | % | 1.51 | ±0.08 |
Mn | % | 0.010 | ±0.002 |
Mo | % | 52.15 | ±0.60 |
Pb | % | 0.021 | ±0.004 |
S | % | 35.1 | ±3.1 |
Si | % | 2.78 | ±0.36 |
Zn | % | 0.028 | ±0.008 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Al | 0.10 | ±0.04 | |
As | ppm | 143 | ±65 |
Au | g/t | 6.38 | ±0.26 |
Co | % | 0.005 | ±0.004 |
Cu (soluble) | % | 0.024 | ±0.009 |
Ni | % | 0.007 | ±0.004 |
Se | ppm | 0.030 | 0.015 |
QCRM-5-068 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Low grade Copper Ore or Molybdenum Concentrate and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-069Copper Concentrate – 15.54% Cu; 98.2g/t Ag; 1474ppm As, 3.74% Mo – Rio Tinto Kennecott, USA
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Ag | g/t | 98.2 | ±1.3 |
Al | % | 1.44 | ±0.07 |
As | ppm | 1474 | ±23 |
Ca | % | 0.87 | ±0.03 |
Co | % | 0.008 | ±0.002 |
Cu | % | 15.54 | ±0.12 |
Fe | % | 19.23 | ±0.34 |
Mg | % | 1.45 | ±0.07 |
Mn | % | 0.030 | ±0.004 |
Mo | % | 3.74 | ±0.05 |
Ni | % | 0.009 | ±0.002 |
Pb | % | 0.23 | ±0.01 |
S | % | 25.17 | ±0.69 |
Zn | % | 0.224 | ±0.008 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Au | g/t | 9.05 | ±0.48 |
Bi | % | 0.016 | ±0.015 |
Cu (soluble) | % | 0.53 | ±0.18 |
Se | ppm | 128 | ±19 |
Si | % | 11.47 | ±0.50 |
QCRM-5-069 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Concentrate and as a calibration standard for the calibration of equipment used for analysing similar materials.
This document was updated, as more data became available for As, Bi, Mo and Se. Only the data for these for analytes were received during this update, with two of the analytes becoming certifiable.
QCRM-5-070Copper Tails – 0.042% Cu; 0.73g/t Ag; 83.1ppm Mo – Rio Tinto Kennecott, USA
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Ca | % | 0.87 | ±0.11 |
Cu | % | 15.54 | ±0.004 |
Fe | % | 19.23 | ±0.07 |
Mn | % | 1.45 | ±0.002 |
Mo | % | 0.030 | ±2.5 |
S | % | 3.74 | ±0.04 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Ag | g/t | 0.73 | ±0.44 |
Al | % | 4.73 | ±0.16 |
As | ppm | 21 | ±11 |
Au | g/t | 0.09 | ±0.02 |
Co | % | 0.002 | ±0.002 |
Cu (Soluble) | % | 0.016 | ±0.004 |
Mg | % | 1.74 | ±0.05 |
Ni | % | 0.003 | ±0.002 |
Pb | % | 0.005 | ±0.002 |
Si | % | 32.13 | ±0.84 |
Zn | % | 0.008 | ±0.002 |
QCRM-5-070 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Tails and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-078Copper Slag – 1.64% Cu; 34.8% Fe; 14.1% Si – Dundee Precious Metals, Namibia
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 1.13 | ±0.15 |
Co | % | 0.011 | ±0.004 |
Cu | % | 1.64 | ±0.11 |
Cu (soluble) | % | 0.76 | ±0.05 |
Fe | % | 34.8 | ±1.5 |
Mn | % | 0.052 | ±0.006 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Ag | g/t | 18.4 | ±4.4 |
As | % | 0.45 | ±0.11 |
Ca | % | 3.24 | ±0.18 |
Mg | % | 0.71 | ±0.04 |
Ni | % | 0.009 | ±0.002 |
S | % | 0.68 | ±0.07 |
Si | % | 14.1 | ±2.0 |
QCRM-5-078 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for low grade copper and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-079Copper Concentrate -24.56% Cu, 18.97% Fe; 33.8g/t Ag – Palabora Mining Company
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Cu | % | 24.56 | ±0.21 |
Fe | % | 18.97 | ±0.46 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Ag | g/t | 33.8 | ±5.9 |
Al | % | 0.40 | ±0.07 |
Ca | % | 8.20 | ±0.73 |
Co | % | 0.09 | ±0.01 |
Cu (Soluble) | % | 1.28 | ±0.61 |
Mg | % | 2.33 | ±0.21 |
Mn | % | 0.06 | ±0.01 |
Ni | % | 0.14 | ±0.02 |
Pb | % | 0.02 | ±0.01 |
S | % | 17.7 | ±1.1 |
Si | % | 2.48 | ±0.73 |
Zn | % | 0.06 | ±0.01 |
QCRM-5-079 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Concentrate and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-080Copper Tails – 0.60% Cu; 14.54% Fe – Palabora Mining Company
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.76 | ±0.04 |
Cu | % | 0.60 | ±0.02 |
Fe | % | 14.65 | ±0.41 |
Mg | % | 4.53 | ±0.20 |
Mn | % | 0.11 | ±0.01 |
Zn | % | 0.009 | ±0.004 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Au | g/t | 0.06 | ±0.02 |
Ca | % | 22.28 | ±0.65 |
Co | % | 0.016 | ±0.004 |
Cu (Soluble) | % | 0.15 | ±0.01 |
Ni | % | 0.012 | ±0.002 |
Pb | % | 0.010 | ±0.006 |
S | % | 0.47 | ±0.11 |
Si | % | 3.17 | ±0.38 |
QCRM-5-080 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Tails and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-081Copper Ore – 1.93% Cu, 2.53% Fe – Lubambe Copper Mine, Zambia
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 8.89 | ±0.53 |
Ca | % | 0.27 | ±0.03 |
Co | % | 0.013 | ±0.002 |
Cu | % | 1.93 | ±0.04 |
Cu (soluble) | % | 0.42 | ±0.03 |
Fe | % | 2.53 | ±0.12 |
Mg | % | 1.38 | ±0.06 |
Mn | % | 0.022 | ±0.002 |
Pb | 0.004 | ±0.002 | |
Zn | % | 0.005 | ±0.004 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Ni | % | 0.005 | ±0.002 |
S | % | 0.51 | ±0.10 |
Si | % | 27.60 | ±0.93 |
QCRM-5-081 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for copper ore and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-082Copper Concentrate – 24.91% Cu; 6.14% Zn;11.79% Fe – Kalahari Copperbelt, Botswana
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Cu | % | 24.91 | ±0.35 |
Fe | % | 11.79 | ±0.87 |
Certified values | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 1.03 | ±0.30 |
As | % | 1.33 | ±0.34 |
Ca | % | 3.01 | ±0.37 |
Co | % | 0.60 | ±0.06 |
Cu (soluble) | % | 10.9 | ±1.9 |
Mg | % | 1.43 | ±0.32 |
Mn | % | 0.20 | ±0.03 |
Ni | % | 0.09 | ±0.02 |
Pb | % | 0.21 | ±0.03 |
S | % | 11.4 | ±2.0 |
Si | % | 4.46 | ±0.28 |
Zn | % | 6.14 | ±0.49 |
QCRM-5-082 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Concentrate and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-5-083Copper Tails – 0.37% Cu, 2.43% Fe – Lubambe Copper Mine, Zambia
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Ca | % | 0.35 | ±0.05 |
Cu | % | 0.37 | ±0.03 |
Fe | % | 2.42 | ±0.12 |
Mg | % | 1.44 | ±0.09 |
Certified values | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 9.23 | ±0.33 |
Co | % | 0.010 | ±0.002 |
Cu (soluble) | % | 0.20 | ±0.03 |
Mn | % | 0.021 | ±0.002 |
S | % | 0.06 | ±0.03 |
Si | % | 25.8 | ±3.2 |
Zn | % | 0.01 | ±0.01 |
QCRM-5-083 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Tails and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-087Copper Ore – 4.88% Cu, 1.93% Fe – Kinsenda Copper Mine, DRC
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Cu | % | 4.88 | ±0.07 |
Cu (soluble) | % | 0.71 | ±0.14 |
Fe | % | 1.93 | ±0.19 |
Mg | % | 0.28 | ±0.07 |
S | % | 1.68 | ±0.17 |
Certified values | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Ag | g/t | 3.8 | ±2.1 |
Al | % | 4.52 | ±0.36 |
Ca | % | 0.13 | ±0.05 |
Co | % | 0.006 | ±0.002 |
Mn | % | 0.012 | ±0.004 |
Pb | % | 0.007 | ±0.004 |
Si | % | 29.56 | ±2.2 |
Zn | % | 0.010 | ±0.007 |
QCRM-5-087 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Ore and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-088Copper Concentrate -50.15% Cu, 43.4g/t Ag – Kinsenda Copper Mine, DRC
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Ag | g/t | 43.4 | ±3.1 |
Al | % | 1.56 | ±0.11 |
Ca | % | 0.06 | ±0.04 |
Co | % | 0.028 | ±0.004 |
Cu | % | 50.15 | ±0.50 |
Cu (soluble) | % | 6.13 | ±0.79 |
Fe | % | 5.14 | ±0.18 |
Mg | % | 0.11 | ±0.01 |
Mn | % | 0.012 | ±0.002 |
S | % | 17.45 | ±0.76 |
Zn | % | 0.008 | ±0.002 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Au | g/t | 0.20 | ±0.08 |
Ni | % | 0.005 | ±0.002 |
Pb | % | 0.007 | ±0.002 |
Si | % | 6.96 | ±0.67 |
QCRM-5-088 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for copper concentrate and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-089Copper Tails – 0.58% Cu, 1.27% Fe – Kinsenda Copper Mine, DRC
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Ca | % | 0.09 | ±0.02 |
Cu | % | 0.58 | ±0.03 |
Mg | % | 0.16 | ±0.02 |
Mn | % | 0.011 | ±0.002 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 4.54 | ±0.33 |
Co | % | 0.007 | ±0.004 |
Cu (soluble) | % | 0.24 | ±0.01 |
Fe | % | 1.27 | ±0.03 |
S | % | 0.13 | ±0.04 |
Zn | % | 0.007 | ±0.002 |
QCRM-5-089 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Tails and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-096Copper Concentrate – 29.48% Cu; 311g/t Ag; 17.22g/t Au; 1.84% As; 2.59% Zn – Dundee Precious Metals, Namibia
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Ag | g/t | 311 | ±5.6 |
Al | % | 0.85 | ±0.06 |
As | % | 1.84 | ±0.04 |
Au | g/t | 17.22 | ±0.53 |
Ca | % | 2.38 | ±0.12 |
Co | % | 0.009 | ±0.002 |
Cu | % | 29.48 | ±0.43 |
Cu (Soluble) | % | 4.37 | ±0.40 |
Mg | % | 0.41 | ±0.03 |
Mn | % | 0.04 | ±0.01 |
Ni | % | 0.009 | ±0.004 |
S | % | 10.72 | ±0.37 |
Zn | % | 2.59 | ±0.17 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Bi | ppm | 676 | ±38 |
Cd | ppm | 74 | ±15 |
Fe | % | 19.92 | ±0.97 |
Pb | % | 2.29 | ±0.08 |
Sb | % | 0.57 | ±0.15 |
Si | % | 6.77 | ±0.30 |
QCRM-5-096 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Concentrate and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-100Copper Concentrate – 21.78% Cu; 604g/t Ag – Dundee Precious Metals, Namibia
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Ag | g/t | 604 | ±13 |
Al | % | 2.91 | ±0.09 |
As | ppm | 295 | ±21 |
Au | g/t | 0.27 | ±0.03 |
Ca | % | 2.52 | ±0.13 |
Cu | % | 21.78 | ±0.11 |
Cu (Soluble) | % | 16.02 | ±0.38 |
Fe | % | 7.51 | ±0.26 |
Mg | % | 1.00 | ±0.05 |
Mn | % | 0.052 | ±0.002 |
Pb | % | 1.87 | ±0.03 |
S | % | 2.24 | ±0.06 |
Si | % | 14.77 | ±0.30 |
Zn | % | 0.036 | ±0.004 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Bi | ppm | 268 | ±67 |
Cd | ppm | 21.5 | ±7.3 |
Fe | % | 0.007 | ±0.002 |
Pb | % | 0.004 | ±0.002 |
Sb | ppm | 58 | ±17 |
QCRM-5-100 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Concentrate and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-108Copper Matte – 51.85% Cu; 451g/t Ag; 36.1g/t Au; 1.41% Pb – Dundee Precious Metals, Namibia
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Ag | g/t | 451 | ±5 |
Al | % | 0.41 | ±0.12 |
As | % | 0.37 | ±0.06 |
Au | g/t | 36.1 | ±0.7 |
Ca | % | 1.19 | ±0.09 |
Cu | % | 51.85 | ±0.42 |
Fe | % | 11.67 | ±0.33 |
Mg | % | 0.39 | ±0.07 |
Pb | % | 1.41 | ±0.09 |
S | % | 13.96 | ±0.44 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Bi | ppm | 604 | ±52 |
Cd | ppm | 40 | ±11 |
Co | % | 0.005 | ±0.002 |
Cu (soluble) | % | 3.19 | ±0.53 |
Mn | % | 0.014 | ±0.002 |
Ni | % | 0.018 | ±0.002 |
Sb | % | 0.17 | ±0.02 |
Si | % | 4.50 | ±0.19 |
Zn | % | 0.72 | ±0.05 |
QCRM-5-108 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Concentrate and as a calibration standard for the calibration of equipment used for analysing similar materials.
This document has been amended, as more data became available (through commercial analysis), thus enabling the certification of additional analytes.
QCRM-5-114Copper Concentrate – 25.92% Cu, 20.5% Fe – Palabora Mining Company
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Ag | % | 30.1 | ±2.3 |
Al | % | 0.36 | ±0.04 |
Ca | % | 7.80 | ±0.42 |
Co | % | 0.095 | ±0.006 |
Cu | % | 26.05 | ±0.16 |
Cu (Soluble) | % | 1.19 | ±0.10 |
Fe | % | 20.06 | ±0.44 |
Mg | % | 2.15 | ±0.10 |
Mn | % | 0.042 | ±0.002 |
Pb | % | 0.016 | ±0.004 |
S | % | 19.86 | ±0.54 |
Zn | % | 0.07 | ±0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Au | g/t | 1.69 | ±0.17 |
Ni | % | 0.15 | ±0.01 |
Si | % | 1.61 | ±0.11 |
QCRM-5-114 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Concentrate and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-119Copper Ore – 0.47% Cu; 7.48% Fe – Minecera Caraiba, Brazil
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Ca | % | 3.42 | ±0.31 |
Co | 0.008 | ±0.002 | |
Cu | % | 0.47 | ±0.01 |
Cu (Soluble) | % | 0.07 | ±0.02 |
Fe | % | 7.45 | ±0.23 |
Mg | % | 4.00 | ±0.13 |
Mn | % | 0.11 | ±0.01 |
Ni | % | 0.029 | ±0.004 |
S | % | 0.56 | ±0.03 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 7.02 | ±0.23 |
Pb | % | 0.008 | ±0.004 |
Si | % | 26.47 | ±0.67 |
Zn | % | 0.014 | ±0.002 |
QCRM-5-119 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Ore and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-124Copper Concentrate – 25.42% Cu, 19.85% Fe – Palabora Mining Company
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.85 | ±0.04 |
Ca | % | 6.21 | ±0.44 |
Co | % | 0.13 | ±0.01 |
Cu | % | 25.42 | ±0.22 |
Cu (Soluble) | % | 1.81 | ±0.50 |
Fe | % | 19.85 | ±0.66 |
Mg | % | 1.76 | ±0.07 |
Mn | % | 0.038 | ±0.002 |
S | % | 16.43 | ±0.43 |
Si | % | 5.47 | ±0.54 |
Zn | % | 0.067 | ±0.008 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Ag | g/t | 38.6 | ±2.2 |
Ni | % | 0.28 | ±0.02 |
Pb | % | 0.024 | ±0.006 |
QCRM-5-124 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Concentrate and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-129Copper Tails – 0.58% Cu, 1.27% Fe – Metalkol RTR, DRC
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 3.20 | ±0.09 |
Ca | % | 0.95 | ±0.03 |
Co | % | 0.045 | ±0.002 |
Cu | % | 0.095 | ±0.002 |
Cu (Soluble) | % | 0.058 | ±0.002 |
Fe | % | 1.22 | ±0.03 |
Mg | % | 1.72 | ±0.04 |
Mn | % | 0.031 | ±0.002 |
Ni | μg/g | 12.6 | ±2.9 |
Pb | μg/g | 24.1 | ±5.7 |
S | % | 0.65 | ±0.02 |
Zn | μg/g | 69.3 | ±8.3 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Si | % | 38.9 | ±1.0 |
U | μg/g | 16.2 | ±2.8 |
QCRM-5-129 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Tails and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-131Copper Ore
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Co | % | 0.30 | ±0.02 |
Cu | % | 1.36 | ±0.02 |
Mg | % | 1.56 | ±0.11 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 2.84 | ±0.29 |
Cu (Soluble) | % | 1.28 | ±0.08 |
Fe | % | 1.13 | ±0.07 |
Mn | % | 0.057 | ±0.005 |
Ni | % | 0.005 | ±0.003 |
Si | % | 38.8 | ±1.7 |
Zn | % | 0.008 | ±0.003 |
QCRM-5-131 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Ore and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-134Copper Ore
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 7.02 | ±0.17 |
Ca | % | 3.54 | ±0.24 |
Co | % | 0.008 | ±0.002 |
Cu | % | 0.52 | ±0.02 |
Fe | % | 7.58 | ±0.16 |
Mg | % | 3.94 | ±0.10 |
Ni | % | 0.042 | ±0.005 |
S | % | 0.65 | ±0.03 |
Zn | % | 0.014 | ±0.001 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Cu (Soluble) | % | 0.08 | ±0.02 |
Mn | % | 0.107 | ±0.006 |
Si | % | 28.1 | ±2.4 |
QCRM-5-134 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Ore and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-138Copper Ore
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Ca | % | 10.2 | ±1.2 |
Co | % | 0.013 | ±0.005 |
Cu | % | 0.24 | ±0.01 |
Cu (Soluble) | % | 0.07 | ±0.01 |
Fe | % | 25.00 | ±0.94 |
Mg | % | 5.21 | ±0.42 |
Mn | % | 0.16 | ±0.02 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 2.67 | ±0.14 |
Ni | % | 0.014 | ±0.002 |
S | % | 0.17 | ±0.04 |
Si | % | 10.98 | ±0.80 |
Zn | % | 0.017 | ±0.004 |
QCRM-5-138 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Ore and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-141Copper Ore
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 0.21 | ±0.05 |
Co | % | 0.007 | ±0.002 |
Cu | % | 1.17 | ±0.01 |
Fe | % | 11.58 | ±0.27 |
Mg | % | 4.67 | ±0.22 |
Mn | % | 0.088 | ±0.002 |
Ni | % | 0.011 | ±0.002 |
S | % | 0.92 | ±0.05 |
Zn | % | 0.004 | ±0.002 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 25.29 | ±0.61 |
Ni | % | 0.20 | ±0.02 |
S | % | 0.016 | ±0.002 |
Si | % | 0.79 | ±0.05 |
QCRM-5-141 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Ore and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-146Copper Concentrate
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Ag | μg/g | 279.6 | ±4.5 |
Al | % | 1.17 | ±0.03 |
Ca | % | 2.13 | ±0.04 |
Cd | μg/g | 50.0 | ±6.3 |
Cu | % | 25.62 | ±0.08 |
Cu (Soluble) | % | 0.69 | ±0.08 |
Fe | % | 22.98 | ±0.30 |
Mg | % | 0.13 | ±0.01 |
Mn | μg/g | 780 | ±23 |
Ni | μg/g | 159 | ±18 |
Pb | % | 0.37 | ±0.01 |
S | % | 27.13 | ±0.43 |
Si | % | 5.41 | ±0.18 |
Zn | % | 0.59 | ±0.02 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | g/t | 0.40 | ±0.05 |
Ni | % | 0.79 | ±0.09 |
S | μg/g | 116 | ±10 |
QCRM-5-146 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Concentrate and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-148Copper Ore
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Co | % | 0.008 | ±0.003 |
Cu | % | 0.91 | ±0.04 |
Mn | % | 0.097 | ±0.007 |
Zn | % | 0.004 | ±0.001 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | g/t | 0.18 | ±0.03 |
Ca | % | 24.9 | ±1.7 |
Cu (Soluble) | % | 0.18 | ±0.02 |
Fe | % | 14.2 | ±1.0 |
Mg | % | 4.12 | ±0.18 |
Ni | % | 0.012 | ±0.002 |
S | % | 0.79 | ±0.13 |
QCRM-5-148 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Ore and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-151Copper Ore
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Cu | % | 1.02 | ±0.02 |
Fe | % | 7.74 | ±0.18 |
Mg | % | 4.00 | ±0.13 |
Mn | % | 0.067 | ±0.004 |
Pb | % | 0.006 | ±0.002 |
S | % | 1.60 | ±0.11 |
Zn | % | 0.003 | ±0.001 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | g/t | 0.12 | ±0.03 |
Ca | % | 27.02 | ±0.72 |
Co | % | 0.015 | ±0.005 |
Cu (Soluble) | % | 0.080 | ±0.005 |
Ni | % | 0.020 | ±0.002 |
Si | % | 0.68 | ±0.21 |
QCRM-5-148 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Ore and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-152Copper Concentrate
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Ag | μg/g | 53.6 | ±1.5 |
Al | % | 1.47 | ±0.07 |
As | μg/g | 108 | ±16 |
Au | g/t | 2.12 | ±0.27 |
Ca | % | 0.92 | ±0.05 |
Cd | μg/g | 40.5 | ±3.2 |
Co | μg/g | 697 | ±26 |
Cu | % | 27.36 | ±0.17 |
Fe | % | 21.01 | ±0.70 |
Mg | % | 2.14 | ±0.09 |
Mn | % | 0.115 | ±0.010 |
Ni | μg/g | 753 | ±27 |
Pb | % | 0.14 | ±0.01 |
S | % | 8.80 | ±0.24 |
Si | % | 7.62 | ±0.29 |
Zn | % | 0.70 | ±0.03 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
C | % | 0.28 | ±0.03 |
Cu (Soluble) | % | 7.39 | ±0.41 |
F | μg/g | 292 | ±16 |
QCRM-5-152 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Concentrate and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-163Copper Tails
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Ca | % | 6.04 | ±0.26 |
Cu | % | 0.70 | ±0.01 |
Fe | % | 3.86 | ±0.13 |
Mg | % | 0.90 | ±0.05 |
Mn | % | 0.20 | ±0.01 |
Si | % | 30.1 | ±1.6 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 3.95 | ±0.10 |
Co | μg/g | 33 | ±12 |
Cu (Soluble) | % | 0.58 | ±0.05 |
Ni | μg/g | 36.5 | ±5.8 |
Pb | % | 0.026 | ±0.002 |
S | % | 0.23 | ±0.01 |
Zn | μg/g | 198 | ±13 |
QCRM-5-163 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Tails and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-165Copper Ore
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Ca | % | 27.5 | ±1.6 |
Co | μg/g | 102 | ±11 |
Cu | % | 0.75 | ±0.01 |
Cu (Soluble) | % | 0.09 | ±0.02 |
Fe | % | 10.53 | ±0.17 |
Mg | % | 4.48 | ±0.13 |
Mn | μg/g | 650 | ±29 |
S | % | 1.13 | ±0.07 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 0.17 | ±0.04 |
Ni | μg/g | 180 | ±26 |
Pb | μg/g | 77 | ±12 |
Si | % | 0.62 | ±0.06 |
Zn | μg/g | 34 | ±14 |
QCRM-5-165 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Ore and as a calibration standard for the calibration of equipment used for analysing similar materials.