Ferrochrome
Showing all 27 results
QCRM-1-120Ferrochrome – 51.70% Cr; 0.020% P; 2.74% Si – Samancor FMT Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.051 | ±0.017 |
C | % | 7.56 | ±0.08 |
Co | % | 0.060 | ±0.002 |
Cr | % | 51.70 | ±0.11 |
Fe | % | 36.01 | ±0.32 |
Mn | % | 0.269 | ±0.009 |
Ni | % | 0.174 | ±0.004 |
P | % | 0.020 | ±0.002 |
S | % | 0.041 | ±0.002 |
Si | % | 2.742 | ±0.076 |
Ti | % | 0.355 | ±0.011 |
V | % | 0.327 | ±0.004 |
QCRM-1-120 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for ferro chrome and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-1-141Ferrochrome – 48.32% Cr; 0.031% P; 0.23% Si – Samancor TC Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.07 | ±0.02 |
C | % | 7.66 | ±0.04 |
Co | % | 0.066 | ±0.002 |
Cr | % | 48.32 | ±0.07 |
Fe | % | 42.62 | ±0.19 |
Mn | % | 0.049 | ±0.004 |
Ni | % | 0.215 | ±0.002 |
P | % | 0.031 | ±0.004 |
S | % | 0.122 | ±0.004 |
Si | % | 0.23 | ±0.03 |
Ti | % | 0.035 | ±0.002 |
V | % | 0.348 | ±0.004 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 0.04 | ±0.02 |
QCRM-1-141 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-1-161Ferrochrome – 48.48% Cr; 0.045% P; 5.76% Si – Tubatse Ferrochrome
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.09 | ±0.02 |
C | % | 6.18 | ±0.06 |
Co | % | 0.055 | ±0.002 |
Cr | % | 48.48 | ±0.23 |
Fe | % | 35.45 | ±0.19 |
Mn | % | 1.16 | ±0.04 |
Ni | % | 0.17 | ±0.01 |
P | % | 0.045 | ±0.004 |
S | % | 0.047 | ±0.002 |
Si | % | 5.76 | ±0.04 |
Ti | % | 0.50 | ±0.01 |
V | % | 0.32 | ±0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 0.12 | ±0.06 |
QCRM-1-161 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-1-165Ferrochrome – 49.96% Cr; 0.020% P; 4.16% Si – Samancor FMT Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.10 | ±0.03 |
C | % | 6.56 | ±0.03 |
Co | % | 0.059 | ±0.002 |
Cr | % | 49.96 | ±0.12 |
Fe | % | 37.64 | ±0.15 |
Mn | % | 0.20 | ±0.01 |
Ni | % | 0.185 | ±0.002 |
P | % | 0.020 | ±0.002 |
S | % | 0.045 | ±0.002 |
Si | % | 4.16 | ±0.04 |
Ti | % | 0.34 | ±0.01 |
V | % | 0.34 | ±0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 0.11 | ±0.07 |
QCRM-1-165 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-1-171Ferrochrome – 52.78% Cr; 0.018% P; 0.59% Si – Samancor Middelburg Ferrochrome Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.06 | ±0.02 |
C | % | 8.77 | ±0.07 |
Co | % | 0.058 | ±0.002 |
Cr | % | 52.78 | ±0.18 |
Fe | % | 36.37 | ±0.25 |
Mn | % | 0.33 | ±0.01 |
Ni | % | 0.168 | ±0.004 |
P | % | 0.018 | ±0.002 |
S | % | 0.016 | ±0.002 |
Si | % | 0.59 | ±0.04 |
Ti | % | 0.29 | ±0.01 |
V | % | 0.34 | ±0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 0.03 | ±0.02 |
QCRM-1-171 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-1-175Ferrochrome – 47.83% Cr; 0.018% P; 4.63% Si – Glencore Operations
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.74 | ±0.03 |
C | % | 6.29 | ±0.04 |
Co | % | 0.054 | ±0.002 |
Cr | % | 47.83 | ±0.08 |
Fe | % | 35.23 | ±0.22 |
Mn | % | 0.20 | ±0.01 |
Ni | % | 0.165 | ±0.002 |
P | % | 0.018 | ±0.002 |
S | % | 0.051 | ±0.002 |
Si | % | 4.63 | ±0.05 |
Ti | % | 0.42 | ±0.01 |
V | 0.33 | ±0.01 | |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 0.62 | ±0.02 |
QCRM-1-175 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-1-180Ferrochrome – 49.66% Cr; 0.019% P; 2.53% Si – Samancor FMT Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.06 | ±0.02 |
Co | % | 0.062 | ±0.002 |
Cr | % | 49.66 | ±0.11 |
Fe | % | 39.15 | ±0.28 |
Mn | % | 0.258 | ±0.004 |
Ni | % | 0.198 | ±0.004 |
P | % | 0.019 | ±0.002 |
S | % | 0.063 | ±0.002 |
Si | % | 2.53 | ±0.06 |
Ti | % | 0.30 | ±0.01 |
V | % | 0.35 | ±0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
C | % | 6.93 | ±0.05 |
Mg | % | 0.05 | ±0.02 |
QCRM-1-180 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-1-181Ferrochrome – 49.69% Cr; 0.023% P; 4.04% Si – Samancor FMT Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.05 | ±0.02 |
Co | % | 0.061 | ±0.002 |
Cr | % | 49.69 | ±0.10 |
Fe | % | 38.22 | ±0.29 |
Mn | % | 0.19 | ±0.01 |
Ni | % | 0.184 | ±0.002 |
P | % | 0.023 | ±0.002 |
S | % | 0.057 | ±0.002 |
Si | % | 4.04 | ±0.07 |
Ti | % | 0.38 | ±0.01 |
V | % | 0.364 | ±0.004 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
C | % | 6.65 | ±0.05 |
Mg | % | 0.04 | ±0.03 |
QCRM-1-181 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analyzing similar materials.
QCRM-1-185Ferrochrome – 52.14% Cr; 0.017% P; 3.43% Si – ARM Machadodorp Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.38 | ±0.03 |
C | % | 6.66 | ±0.04 |
Co | % | 0.054 | ±0.002 |
Cr | % | 52.14 | ±0.08 |
Fe | % | 33.88 | ±0.19 |
Mn | % | 0.28 | ±0.01 |
Ni | % | 0.172 | ±0.002 |
P | % | 0.017 | ±0.002 |
S | % | 0.042 | ±0.002 |
Si | % | 3.43 | ±0.04 |
Ti | % | 0.29 | ±0.01 |
V | % | 0.30 | ±0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 0.33 | ±0.04 |
QCRM-1-185 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome (Chrome Metal) and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-195Ferrochrome – 49.11% Cr; 0.018% P; 2.44% Si – Samancor Tubatse Alloy Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.04 | ±0.02 |
C | % | 7.11 | ±0.05 |
Co | % | 0.063 | ±0.002 |
Cr | % | 49.11 | ±0.12 |
Fe | % | 40.24 | ±0.18 |
Mn | % | 0.19 | ±0.01 |
Ni | % | 0.20 | ±0.01 |
P | % | 0.018 | ±0.002 |
S | % | 0.063 | ±0.002 |
Si | % | 2.44 | ±0.05 |
Ti | % | 0.31 | ±0.01 |
V | % | 0.36 | ±0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 0.03 | ±0.03 |
QCRM-1-195 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-200Ferrochrome – 49.84% Cr; 0.019% P; 6.44% Si – Samancor Tubatse Alloy Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.03 | ±0.01 |
C | % | 6.28 | ±0.03 |
Co | % | 0.056 | ±0.002 |
Cr | % | 49.84 | ±0.12 |
Fe | % | 35.91 | ±0.21 |
Mn | % | 0.26 | ±0.01 |
Ni | % | 0.17 | ±0.01 |
P | % | 0.019 | ±0.002 |
S | % | 0.037 | ±0.002 |
Si | % | 6.44 | ±0.05 |
Ti | % | 0.56 | ±0.01 |
V | % | 0.33 | ±0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 0.03 | ±0.02 |
QCRM-1-200 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-204Ferrochrome – 46.62% Cr; 0.019% P; 5.96% Si – Samancor Dikwena Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.05 | ±0.01 |
C | % | 6.10 | ±0.02 |
Co | % | 0.059 | ±0.002 |
Cr | % | 46.62 | ±0.09 |
Fe | % | 37.56 | ±0.14 |
Mn | % | 0.85 | ±0.02 |
Ni | % | 0.184 | ±0.004 |
P | % | 0.019 | ±0.002 |
S | % | 0.074 | ±0.002 |
Si | % | 5.96 | ±0.08 |
Ti | % | 0.56 | ±0.01 |
V | % | 0.40 | ±0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 0.04 | ±0.03 |
QCRM-1-204 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-208Ferrochrome – 49.42% Cr; 5.67% Si – Samancor Tubatse Alloy Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
C | % | 6.58 | ±0.05 |
Co | % | 0.058 | ±0.002 |
Cr | % | 49.42 | ±0.12 |
Fe | % | 36.78 | ±0.18 |
Mn | % | 0.26 | ±0.01 |
Ni | % | 0.17 | ±0.01 |
S | % | 0.043 | ±0.002 |
Si | % | 5.67 | ±0.10 |
Ti | % | 0.59 | ±0.01 |
V | % | 0.34 | ±0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.04 | ±0.02 |
Mg | % | 0.03 | ±0.03 |
P | % | 0.023 | ±0.002 |
QCRM-1-208 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome (Chrome Metal) and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-220Ferrochrome – 53.56% Cr; 0.021% P; 0.29% Si – Samancor Middelburg Ferrochrome Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.08 | ±0.01 |
C | % | 8.87 | ±0.11 |
Co | % | 0.055 | ±0.002 |
Cr | % | 53.56 | ±0.11 |
Fe | % | 35.80 | ±0.37 |
Mn | % | 0.29 | ±0.01 |
Ni | % | 0.15 | ±0.01 |
P | % | 0.021 | ±0.002 |
S | % | 0.024 | ±0.002 |
Si | % | 0.29 | ±0.05 |
Ti | % | 0.14 | ±0.01 |
V | % | 0.34 | ±0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 0.06 | ±0.05 |
QCRM-1-220 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-224Ferrochrome – 50.20% Cr; 0.019% P; 2.55% Si – Samancor FMT Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.10 | ±0.02 |
C | % | 6.83 | ±0.05 |
Co | % | 0.060 | ±0.002 |
Cr | % | 50.20 | ±0.10 |
Fe | % | 38.44 | ±0.15 |
Mn | % | 0.155 | ±0.004 |
Ni | % | 0.184 | ±0.004 |
P | % | 0.019 | ±0.002 |
S | % | 0.055 | ±0.002 |
Si | % | 2.55 | ±0.04 |
Ti | % | 0.275 | ±0.004 |
V | % | 0.35 | ±0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 0.082 | ±0.013 |
QCRM-1-224 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-228Ferrochrome – 49.64% Cr; 0.019% P; 3.33% Si – Glencore Wonderkop Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.14 | ±0.02 |
C | % | 7.22 | ±0.05 |
Co | % | 0.059 | ±0.002 |
Cr | % | 49.64 | ±0.09 |
Fe | % | 37.08 | ±0.18 |
Mn | % | 0.33 | ±0.01 |
S | % | 0.038 | ±0.002 |
Si | % | 3.33 | ±0.03 |
Ti | % | 0.64 | ±0.01 |
V | % | 0.37 | ±.0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 0.11 | ±0.03 |
Ni | % | 0.21 | ±0.01 |
QCRM-1-228 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-232Ferrochrome – 48.74% Cr; 0.019% P; 4.36% Si – Samancor Middelburg Ferrochrome Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.09 | ±0.02 |
C | % | 6.75 | ±0.06 |
Co | % | 0.058 | ±0.002 |
Cr | % | 48.74 | ±0.10 |
Fe | % | 38.21 | ±0.18 |
Mn | % | 0.257 | ±0.004 |
Ni | % | 0.173 | ±0.002 |
P | % | 0.019 | ±0.002 |
S | % | 0.042 | ±0.002 |
Si | % | 4.36 | ±0.06 |
Ti | % | 0.55 | ±0.01 |
V | % | 0.35 | ±.0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 0.04 | ±0.02 |
QCRM-1-232 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-236Ferrochrome – 40.74% Cr; 0.014% P; 6.46% Si – Glencore Lydenberg Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 2.43 | ±0.14 |
C | % | 5.82 | ±0.04 |
Co | % | 0.047 | ±0.002 |
Cr | % | 40.74 | ±0.23 |
Fe | % | 29.46 | ±0.36 |
Mn | % | 0.38 | ±0.01 |
Ni | % | 0.139 | ±0.002 |
P | % | 0.014 | ±0.002 |
S | % | 0.057 | ±0.002 |
Si | % | 6.46 | ±0.07 |
Ti | % | 0.45 | ±0.01 |
V | % | 0.27 | ±.0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 1.72 | ±0.20 |
QCRM-1-236 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-240Chrome Concentrate
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 0.61 | ±0.04 |
C | % | 5.94 | ±0.06 |
Co | % | 0.063 | ±0.002 |
Cr | % | 44.23 | ±0.13 |
Fe | % | 38.85 | ±0.38 |
Mn | % | 0.262 | ±0.004 |
Ni | % | 0.23 | ±0.01 |
P | % | 0.017 | ±0.002 |
S | % | 0.075 | ±0.004 |
Si | % | 5.20 | ±0.07 |
Ti | % | 0.50 | ±0.01 |
V | % | 0.33 | ±0.01 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
C | % | 0.047 | ±0.013 |
QCRM-1-240 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Chrome Concentrate and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-245Ferrochrome
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 0.42 | ±0.03 |
C | % | 6.18 | ±0.05 |
Co | % | 0.059 | ±0.002 |
Cr | % | 46.47 | ±0.19 |
Fe | % | 36.64 | ±0.20 |
Mn | % | 0.27 | ±0.01 |
Ni | % | 0.20 | ±0.01 |
P | % | 0.026 | ±0.002 |
S | % | 0.044 | ±0.002 |
Si | % | 5.90 | ±0.06 |
Ti | % | 0.62 | ±0.01 |
V | % | 0.34 | ±0.01 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Mg | % | 0.29 | ±0.05 |
QCRM-1-245 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-249Ferrochrome – 48.92% Cr; 0.019% P; 4.87% Si – Glencore Boshoek Smelter
In stock
Certified values | |||
---|---|---|---|
Analytes | Units | Concentrations | Expanded uncertainty |
Al | % | 0.17 | ±0.03 |
C | % | 6.61 | ±0.04 |
Co | % | 0.059 | ±0.002 |
Cr | % | 48.92 | ±0.10 |
Fe | % | 36.85 | ±0.23 |
Mn | % | 0.30 | ±0.01 |
Ni | % | 0.21 | ±0.01 |
P | % | 0.019 | ±0.002 |
S | % | 0.040 | ±0.002 |
Si | % | 4.87 | ±0.09 |
Ti | % | 0.69 | ±0.01 |
ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
Analytes | Units | Concentrations | Expanded uncertainty |
Mg | % | 0.12 | ±0.03 |
V | % | 0.35 | ±0.01 |
QCRM-1-249 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-253Ferrochrome – 48.74% Cr; 0.015% P; 0.37% Si – Samancor Middelburg Ferrochrome Smelter
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 0.08 | ±0.02 |
C | % | 8.98 | ±0.08 |
Co | % | 0.058 | ±0.001 |
Cr | % | 52.50 | ±0.07 |
Fe | % | 36.62 | ±0.16 |
Mn | % | 0.31 | ±0.01 |
Ni | % | 0.163 | ±0.004 |
P | % | 0.015 | ±0.002 |
Si | % | 0.38 | ±0.03 |
Ti | % | 0.134 | ±0.002 |
V | % | 0.34 | ±0.01 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Mg | % | 0.049 | ±0.006 |
S | % | 0.015 | ±0.002 |
QCRM-1-253 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-257Ferrochrome
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 0.48 | ±0.02 |
C | % | 7.08 | ±0.08 |
Co | % | 0.058 | ±0.001 |
Cr | % | 48.77 | ±0.17 |
Fe | % | 36.51 | ±0.18 |
Mn | % | 0.30 | ±0.01 |
Ni | % | 0.178 | ±0.004 |
P | % | 0.019 | ±0.001 |
Si | % | 3.41 | ±0.06 |
Ti | % | 0.57 | ±0.01 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Mg | % | 0.36 | ±0.03 |
S | % | 0.046 | ±0.004 |
V | % | 0.33 | ±0.01 |
QCRM-1-257 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-277Ferrochrome
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 0.50 | ±0.03 |
C | % | 6.29 | ±0.05 |
Co | % | 0.058 | ±0.001 |
Cr | % | 46.51 | ±0.11 |
Mn | % | 0.263 | ±0.004 |
Ni | % | 0.174 | ±0.004 |
P | % | 0.018 | ±0.002 |
S | % | 0.068 | ±0.002 |
Ti | % | 0.58 | ±0.01 |
V | % | 0.33 | ±0.01 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Fe | % | 36.37 | ±0.28 |
Mg | % | 0.38 | ±0.04 |
Si | % | 5.77 | ±0.07 |
QCRM-1-277 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-285Ferrochrome
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
C | % | 6.77 | ±0.05 |
Co | % | 0.058 | ±0.002 |
Cr | % | 49.78 | ±0.16 |
Fe | % | 36.28 | ±0.21 |
Mn | % | 0.272 | ±0.004 |
Ni | % | 0.170 | ±0.004 |
P | % | 0.018 | ±0.002 |
S | % | 0.034 | ±0.002 |
Si | % | 5.27 | ±0.07 |
Ti | % | 0.58 | ±0.01 |
V | % | 0.36 | ±0.01 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 0.04 | ±0.28 |
Mg | % | 0.02 | ±0.04 |
QCRM-1-285 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-286Ferrochrome
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 0.11 | ±0.02 |
C | % | 5.97 | ±0.07 |
Co | % | 0.056 | ±0.001 |
Cr | % | 48.57 | ±0.10 |
Fe | % | 35.74 | ±0.25 |
Mn | % | 0.223 | ±0.004 |
Ni | % | 0.161 | ±0.006 |
P | % | 0.016 | ±0.002 |
S | % | 0.033 | ±0.001 |
Si | % | 7.39 | ±0.10 |
Ti | % | 0.61 | ±0.01 |
V | % | 0.37 | ±0.01 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Mg | % | 0.09 | ±0.03 |
QCRM-1-286 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-1-296Ferrochrome
In stock
CERTIFIED VALUES | |||
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Al | % | 0.15 | ±0.02 |
C | % | 5.97 | ±0.07 |
Co | % | 0.058 | ±0.001 |
Cr | % | 48.78 | ±0.13 |
Fe | % | 36.02 | ±0.22 |
Mn | % | 0.240 | ±0.006 |
Ni | % | 0.172 | ±0.004 |
P | % | 0.018 | ±0.002 |
S | % | 0.037 | ±0.002 |
Si | % | 6.56 | ±0.07 |
Ti | % | 0.54 | ±0.01 |
V | % | 0.36 | ±0.01 |
ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
Mg | % | 0.14 | ±0.05 |
QCRM-1-296 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Ferrochrome and as a calibration standard for the calibration of equipment used for analysing similar materials.