Copper Tails
Showing all 6 results
QCRM-5-070Copper Tails – 0.042% Cu; 0.73g/t Ag; 83.1ppm Mo – Rio Tinto Kennecott, USA
In stock
| Certified values | |||
|---|---|---|---|
| Analytes | Units | Concentrations | Expanded uncertainty |
| Ca | % | 0.87 | ±0.11 |
| Cu | % | 15.54 | ±0.004 |
| Fe | % | 19.23 | ±0.07 |
| Mn | % | 1.45 | ±0.002 |
| Mo | % | 0.030 | ±2.5 |
| S | % | 3.74 | ±0.04 |
| ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
| Analytes | Units | Concentrations | Expanded uncertainty |
| Ag | g/t | 0.73 | ±0.44 |
| Al | % | 4.73 | ±0.16 |
| As | ppm | 21 | ±11 |
| Au | g/t | 0.09 | ±0.02 |
| Co | % | 0.002 | ±0.002 |
| Cu (Soluble) | % | 0.016 | ±0.004 |
| Mg | % | 1.74 | ±0.05 |
| Ni | % | 0.003 | ±0.002 |
| Pb | % | 0.005 | ±0.002 |
| Si | % | 32.13 | ±0.84 |
| Zn | % | 0.008 | ±0.002 |
QCRM-5-070 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Tails and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-080Copper Tails – 0.60% Cu; 14.54% Fe – Palabora Mining Company
In stock
| Certified values | |||
|---|---|---|---|
| Analytes | Units | Concentrations | Expanded uncertainty |
| Al | % | 0.76 | ±0.04 |
| Cu | % | 0.60 | ±0.02 |
| Fe | % | 14.65 | ±0.41 |
| Mg | % | 4.53 | ±0.20 |
| Mn | % | 0.11 | ±0.01 |
| Zn | % | 0.009 | ±0.004 |
| ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
| Analytes | Units | Concentrations | Expanded uncertainty |
| Au | g/t | 0.06 | ±0.02 |
| Ca | % | 22.28 | ±0.65 |
| Co | % | 0.016 | ±0.004 |
| Cu (Soluble) | % | 0.15 | ±0.01 |
| Ni | % | 0.012 | ±0.002 |
| Pb | % | 0.010 | ±0.006 |
| S | % | 0.47 | ±0.11 |
| Si | % | 3.17 | ±0.38 |
QCRM-5-080 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Tails and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-083Copper Tails – 0.37% Cu, 2.43% Fe – Lubambe Copper Mine, Zambia
In stock
| Certified values | |||
|---|---|---|---|
| Analytes | Units | Concentrations | Expanded uncertainty |
| Ca | % | 0.35 | ±0.05 |
| Cu | % | 0.37 | ±0.03 |
| Fe | % | 2.42 | ±0.12 |
| Mg | % | 1.44 | ±0.09 |
| Certified values | |||
| Analytes | Units | Concentrations | Expanded uncertainty |
| Al | % | 9.23 | ±0.33 |
| Co | % | 0.010 | ±0.002 |
| Cu (soluble) | % | 0.20 | ±0.03 |
| Mn | % | 0.021 | ±0.002 |
| S | % | 0.06 | ±0.03 |
| Si | % | 25.8 | ±3.2 |
| Zn | % | 0.01 | ±0.01 |
QCRM-5-083 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Tails and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-089Copper Tails – 0.58% Cu, 1.27% Fe – Kinsenda Copper Mine, DRC
In stock
| Certified values | |||
|---|---|---|---|
| Analytes | Units | Concentrations | Expanded uncertainty |
| Ca | % | 0.09 | ±0.02 |
| Cu | % | 0.58 | ±0.03 |
| Mg | % | 0.16 | ±0.02 |
| Mn | % | 0.011 | ±0.002 |
| ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
| Analytes | Units | Concentrations | Expanded uncertainty |
| Al | % | 4.54 | ±0.33 |
| Co | % | 0.007 | ±0.004 |
| Cu (soluble) | % | 0.24 | ±0.01 |
| Fe | % | 1.27 | ±0.03 |
| S | % | 0.13 | ±0.04 |
| Zn | % | 0.007 | ±0.002 |
QCRM-5-089 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Tails and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-129Copper Tails – 0.58% Cu, 1.27% Fe – Metalkol RTR, DRC
In stock
| Certified values | |||
|---|---|---|---|
| Analytes | Units | Concentrations | Expanded uncertainty |
| Al | % | 3.20 | ±0.09 |
| Ca | % | 0.95 | ±0.03 |
| Co | % | 0.045 | ±0.002 |
| Cu | % | 0.095 | ±0.002 |
| Cu (Soluble) | % | 0.058 | ±0.002 |
| Fe | % | 1.22 | ±0.03 |
| Mg | % | 1.72 | ±0.04 |
| Mn | % | 0.031 | ±0.002 |
| Ni | μg/g | 12.6 | ±2.9 |
| Pb | μg/g | 24.1 | ±5.7 |
| S | % | 0.65 | ±0.02 |
| Zn | μg/g | 69.3 | ±8.3 |
| ASSIGNED VALUES (FOR INFORMATION ONLY) | |||
| Analytes | Units | Concentrations | Expanded uncertainty |
| Si | % | 38.9 | ±1.0 |
| U | μg/g | 16.2 | ±2.8 |
QCRM-5-129 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Tails and as a calibration standard for the calibration of equipment used for analysing similar materials.
QCRM-5-163Copper Tails
In stock
| CERTIFIED VALUES | |||
| ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
| Ca | % | 6.04 | ±0.26 |
| Cu | % | 0.70 | ±0.01 |
| Fe | % | 3.86 | ±0.13 |
| Mg | % | 0.90 | ±0.05 |
| Mn | % | 0.20 | ±0.01 |
| Si | % | 30.1 | ±1.6 |
| ANALYTES | UNITS | CONCENTRATIONS | EXPANDED UNCERTAINTY |
| Al | % | 3.95 | ±0.10 |
| Co | μg/g | 33 | ±12 |
| Cu (Soluble) | % | 0.58 | ±0.05 |
| Ni | μg/g | 36.5 | ±5.8 |
| Pb | % | 0.026 | ±0.002 |
| S | % | 0.23 | ±0.01 |
| Zn | μg/g | 198 | ±13 |
QCRM-5-163 is a certified reference material which is suitable for use as random control samples in routine analytical laboratory quality control, when inserted within a batch of samples and measured in parallel to the unknown. The QCRM can also be used as a control sample in the analysis of samples of a similar type, verification of analytical methods for Copper Tails and as a calibration standard for the calibration of equipment used for analysing similar materials.